Datalogger reading kWh pulses from a utility grid meter and publising it via MQTT
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

18 lines
1.4 KiB

Reference, Quantity, Value, Footprint, Datasheet
C1 C4 ,2,"10U","Capacitor_THT:CP_Radial_D5.0mm_P2.50mm","~"
C2 C3 C5 C6 C7 ,5,"100n","Capacitor_THT:C_Disc_D5.0mm_W2.5mm_P5.00mm","~"
D1 ,1,"BPW34","Connector_PinHeader_2.54mm:PinHeader_1x02_P2.54mm_Vertical","http://www.vishay.com/docs/81521/bpw34.pdf"
D2 ,1,"STATUS","LED_THT:LED_D3.0mm_IRGrey","~"
H1 H2 H3 H4 ,4,"MountingHole","MountingHole:MountingHole_3.2mm_M3_DIN965_Pad","~"
J1 ,1,"8-24V in","TerminalBlock_Phoenix:TerminalBlock_Phoenix_MKDS-1,5-2_1x02_P5.00mm_Horizontal","~"
JP1 ,1,"SET","Connector_PinHeader_2.54mm:PinHeader_1x02_P2.54mm_Vertical","~"
JP2 ,1,"Invert pulse","Connector_PinHeader_2.54mm:PinHeader_1x03_P2.54mm_Vertical","~"
R1 R2 ,2,"10k","Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal","~"
R3 ,1,"33k","Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal","~"
R4 ,1,"1k","Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal","~"
RV1 ,1,"500k","Potentiometer_THT:Potentiometer_ACP_CA9-H5_Horizontal","~"
U1 ,1,"ENC28J60","Connector_PinHeader_2.54mm:PinHeader_2x06_P2.54mm_Vertical","http://www.ti.com/lit/gpn/sn74HC14"
U2 ,1,"TL072","Package_DIP:DIP-8_W7.62mm_LongPads",""
U3 ,1,"Arduino Mini Plus","mtk_processor:Arduino_Mini_Plus",""
U5 ,1,"74HC14","Package_DIP:DIP-14_W7.62mm_LongPads","http://www.ti.com/lit/gpn/sn74HC14"
U6 ,1,"TSR_1-2450","Converter_DCDC:Converter_DCDC_TRACO_TSR-1_THT","http://www.tracopower.com/products/tsr1.pdf"