You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
55 lines
1.5 KiB
55 lines
1.5 KiB
/**
|
|
@file TempSensor.ino
|
|
Modbus-Arduino Example - TempSensor (Modbus Serial)
|
|
Copyright (C) 2023 Pascal JEAN aka epsilonrt
|
|
Copyright (C) 2014 André Sarmento Barbosa
|
|
https://github.com/epsilonrt/modbus-serial
|
|
*/
|
|
|
|
#include <ModbusSerial.h>
|
|
|
|
// Used Pins
|
|
const int SensorPin = A0;
|
|
const int TxenPin = -1; // -1 disables the feature, change that if you are using an RS485 driver, this pin would be connected to the DE and /RE pins of the driver.
|
|
|
|
const byte SlaveId = 14;
|
|
// Modbus Registers Offsets (0-9999)
|
|
const int SensorIreg = 0;
|
|
|
|
#define MySerial Serial // define serial port used, Serial most of the time, or Serial1, Serial2 ... if available
|
|
const unsigned long Baudrate = 38400;
|
|
|
|
// ModbusSerial object
|
|
ModbusSerial mb (MySerial, SlaveId, TxenPin);
|
|
|
|
long ts;
|
|
|
|
void setup() {
|
|
|
|
MySerial.begin (Baudrate); // works on all boards but the configuration is 8N1 which is incompatible with the MODBUS standard
|
|
// prefer the line below instead if possible
|
|
// MySerial.begin (Baudrate, MB_PARITY_EVEN);
|
|
|
|
mb.config (Baudrate);
|
|
mb.setAdditionalServerData ("TEMP_SENSOR"); // for Report Server ID function (0x11)
|
|
|
|
|
|
// Add SensorIreg register - Use addIreg() for analog Inputs
|
|
mb.addIreg (SensorIreg);
|
|
|
|
ts = millis();
|
|
}
|
|
|
|
void loop() {
|
|
|
|
// Call once inside loop() - all magic here
|
|
mb.task();
|
|
|
|
// Read each two seconds
|
|
if (millis() > ts + 2000) {
|
|
|
|
ts = millis();
|
|
// Setting raw value (0-1024)
|
|
mb.Ireg (SensorIreg, analogRead (SensorPin));
|
|
}
|
|
}
|
|
|