# Modbus Library for Arduino
|
|
Allows your Arduino to communicate via Modbus protocol
|
|
|
|
[![GitHub release (latest by date including pre-releases)](https://img.shields.io/github/v/release/epsilonrt/modbus-arduino?include_prereleases)](https://github.com/epsilonrt/modbus-arduino/releases)
|
|
[![PlatformIO Registry](https://badges.registry.platformio.org/packages/epsilonrt/library/modbus-arduino.svg)](https://registry.platformio.org/libraries/epsilonrt/modbus-arduino)
|
|
[![Arduino Registry](https://www.ardu-badge.com/badge/Modbus-Arduino.svg)](https://www.arduinolibraries.info/libraries/modbus-arduino)
|
|
|
|
[![Framework](https://img.shields.io/badge/Framework-Arduino-blue)](https://www.arduino.cc/)
|
|
[![Platform ATMELAVR](https://img.shields.io/badge/Platform-AtmelAVR-blue)](#)
|
|
[![Platform ATMELSAM](https://img.shields.io/badge/Platform-AtmelSAM-blue)](#)
|
|
[![Platform Teensy](https://img.shields.io/badge/Platform-Teensy-green)](#)
|
|
[![Platform ESP8266](https://img.shields.io/badge/Platform-Espressif8266-orange)](#)
|
|
[![Platform ESP32](https://img.shields.io/badge/Platform-Espressif32-orange)](#)
|
|
|
|
---
|
|
|
|
<a href="https://modbus.org/">
|
|
<img src="https://github.com/epsilonrt/modbus-arduino/raw/master/extras/modbus.png" alt="Modbus Logo" align="right" valign="top">
|
|
</a>
|
|
|
|
The Modbus is a master-slave protocol used in industrial automation and can be used in other areas, such as home automation.
|
|
|
|
The Modbus generally uses serial RS-232 or RS-485 as physical layer (then called Modbus Serial) and
|
|
TCP/IP via Ethernet or WiFi (Modbus TCP). But it is also possible to associate the Modbus application protocol on any other physical layer, such as the radio for example (with [MobdusRadio](https://github.com/epsilonrt/modbus-radio) for example).
|
|
|
|
![Modbus Stack](https://github.com/epsilonrt/modbus-arduino/raw/master/extras/modbus-stack.png)
|
|
|
|
In the current version the library allows the Arduino operate **as a slave**, supporting Modbus Serial and
|
|
Modbus over IP. For more information about Modbus see:
|
|
|
|
* [Wikipedia article](https://en.wikipedia.org/wiki/Modbus)
|
|
* [MODBUS Application Protocol Specification](http://www.modbus.org/docs/Modbus_Application_Protocol_V1_1b.pdf)
|
|
* [MODBUS Messaging on TCP/IP Implementation Guide](http://www.modbus.org/docs/Modbus_Messaging_Implementation_Guide_V1_0b.pdf)
|
|
* [MODBUS over serial line specification and implementation guide ](http://www.modbus.org/docs/Modbus_over_serial_line_V1_02.pdf)
|
|
|
|
|
|
|
|
## Features
|
|
|
|
* Operates as a slave (master mode in development)
|
|
* Supports Modbus over Serial line (RS-232 or RS485) and Modbus TCP
|
|
* Reply exception messages for all supported functions
|
|
* Modbus functions supported:
|
|
* 0x01 - Read Coils
|
|
* 0x02 - Read Input Status (Read Discrete Inputs)
|
|
* 0x03 - Read Holding Registers
|
|
* 0x04 - Read Input Registers
|
|
* 0x05 - Write Single Coil
|
|
* 0x06 - Write Single Register
|
|
* 0x0F - Write Multiple Coils
|
|
* 0x10 - Write Multiple Registers
|
|
* 0x11 - Report Server ID
|
|
|
|
A set of examples is available for each of the Modbus-derived classes, for example:
|
|
* [Lamp](https://github.com/epsilonrt/modbus-serial/blob/master/examples/Lamp/Lamp.ino): Use a coil to turn on and off a LED (0x05 and 0x01 functions)
|
|
* [LampDimmer](https://github.com/epsilonrt/modbus-serial/blob/master/examples/LampDimmer/LampDimmer.ino): Use a holding register to control the brightness of a LED (0x06 and 0x03 functions)
|
|
* [Switch](https://github.com/epsilonrt/modbus-serial/blob/master/examples/Switch/Switch.ino): Use a discrete input to read the state of a switch (0x02 function)
|
|
* [TempSensor](https://github.com/epsilonrt/modbus-serial/blob/master/examples/TempSensor/TempSensor.ino): Use a input register to read the temperature from a sensor (0x04 function)
|
|
* [Servo](https://github.com/epsilonrt/modbus-radio/blob/master/examples/Servo/Servo.ino): Use a holding register to control the position of a servo motor (0x06 an 0x03 function). Show how to define boundaries for the register.
|
|
* [LampEncrypted](https://github.com/epsilonrt/modbus-radio/blob/master/examples/LampEncrypted/LampEncrypted.ino): Use a coil to turn on and off a LED (0x05 and 0x01 functions) with encrypted communication.
|
|
|
|
All examples show the use of 0x11 function to report the slave ID.
|
|
|
|
|
|
**Notes:**
|
|
|
|
1. The offsets for registers are 0-based. So be careful when setting your supervisory system or your testing software. If offsets are 1-based, so a register configured as 100 in library should be 101 in this software.
|
|
|
|
2. Early in the library Modbus.h file there is an option to limit the operation
|
|
to the functions of Holding Registers, saving space in the program memory.
|
|
Just comment out the following line:
|
|
|
|
#define USE_HOLDING_REGISTERS_ONLY
|
|
|
|
Thus, only the following functions are supported:
|
|
|
|
* 0x03 - Read Holding Registers
|
|
* 0x06 - Write Single Register
|
|
* 0x10 - Write Multiple Registers
|
|
|
|
You may test the library using the [MbPoll](https://github.com/epsilonrt/mbpoll) software. For example, to turn on the led in the Lamp example, just do:
|
|
|
|
$ mbpoll -m rtu -b38400 -a10 -t0 /dev/tnt1 1
|
|
mbpoll 1.5-2 - ModBus(R) Master Simulator
|
|
Copyright (c) 2015-2023 Pascal JEAN, https://github.com/epsilonrt/mbpoll
|
|
This program comes with ABSOLUTELY NO WARRANTY.
|
|
This is free software, and you are welcome to redistribute it
|
|
under certain conditions; type 'mbpoll -w' for details.
|
|
|
|
Protocol configuration: ModBus RTU
|
|
Slave configuration...: address = [10]
|
|
start reference = 1, count = 1
|
|
Communication.........: /dev/tnt1, 38400-8E1
|
|
t/o 1.00 s, poll rate 1000 ms
|
|
Data type.............: discrete output (coil)
|
|
|
|
Written 1 references.
|
|
|
|
## How to
|
|
|
|
There are five classes corresponding to six headers that may be used:
|
|
|
|
* Modbus-Arduino - Base Library (this repository)
|
|
* [Modbus-Serial](https://github.com/epsilonrt/modbus-serial) - Modbus Serial RTU Library
|
|
* [Modbus-Ethernet](https://github.com/epsilonrt/modbus-ethernet) - Modbus TCP Library (standard Ethernet Shield)
|
|
* [Modbus-EtherCard](https://github.com/epsilonrt/modbus-ethercard) - Modbus TCP Library (for ENC28J60 chip)
|
|
* [Modbus-Esp8266AT](https://github.com/epsilonrt/modbus-esp8266at) - Modbus IP Library (for ESP8266 chip with AT firmware)
|
|
* [Modbus-Radio](https://github.com/epsilonrt/modbus-radio) - Modbus Radio Library (RadioHead compatible chips)
|
|
|
|
By opting for Modbus Serial, TCP or Radio you must include in your sketch the corresponding header :
|
|
|
|
#include <ModbusSerial.h>
|
|
|
|
|
|
## Modbus Jargon
|
|
|
|
In this library was decided to use the terms used in Modbus to the methods names, then is important clarify the names of
|
|
register types:
|
|
|
|
| Register type | Use as | Access | Library methods |
|
|
| -------------------- | ------------------ | ----------------- | ----------------------------- |
|
|
| Coil | Digital Output | Read/Write | addCoil(), coil(), setCoil() |
|
|
| Holding Register | Analog Output | Read/Write | addHreg(), hreg(), setHreg() |
|
|
| Input Status | Digital Input | Read Only | addIsts(), ists(), setIsts() |
|
|
| Input Register | Analog Input | Read Only | addIreg(), ireg(), setIreg() |
|
|
|
|
**Notes:**
|
|
|
|
1. _Input Status_ is sometimes called _Discrete Input_.
|
|
2. _Holding Register_ or just _Register_ is also used to store values in the slave.
|
|
3. Examples of use: A _Coil_ can be used to drive a lamp or LED. A _Holding Register_ to
|
|
store a counter or drive a Servo Motor. A _Input Status_ can be used with a reed switch
|
|
in a door sensor and a _Input Register_ with a temperature sensor.
|
|
|
|
License
|
|
=======
|
|
The code in this repo is licensed under the BSD New License. See LICENSE for more info.
|
|
|
|
|