ModbusSerial.h - Header for ModbusSerial Library
Copyright (C) 2023 Pascal JEAN aka epsilonrt
Copyright (C) 2014 André Sarmento Barbosa
*/
#include <Arduino.h>
#include <Modbus.h>
#pragma once
/**
* @enum MB_PARITY
* @brief Parity
*
* See paragraph [2.5.1 RTU Transmission Mode] from
* MODBUS over serial line specification and implementation guide V1.02
* http://www.modbus.org/docs/Modbus_over_serial_line_V1_02.pdf
*
* The format (11 bits) for each byte in RTU mode is :
* Coding System:
*
* * 8–bit binary
*
* Bits per Byte:
*
* * 1 start bit
* * 8 data bits, least significant bit sent first
* * 1 bit for parity completion
* * 1 stop bit
* .
*
* Even parity is required, other modes ( odd parity, no parity )
* may also be used. In order to ensure a maximum compatibility with
* other products, it is recommended to support also No parity mode.
* The default parity mode must be even parity.
* Remark : the use of no parity requires 2 stop bits.
*/
enum MB_PARITY {
MB_PARITY_NONE = SERIAL_8N2, ///< No parity
MB_PARITY_EVEN = SERIAL_8E1, ///< Even parity
MB_PARITY_ODD = SERIAL_8O1 ///< Odd parity
};
/**
* @class ModbusSerial
* @brief Modbus over serial line Class
*/
class ModbusSerial : public Modbus {
public:
/**
* @brief Constructor
* @param port serial port to use
* @param txenPin if an RS485 circuit is used, this corresponds to the
* pin number connected to the transmit enable (DE) and receive disable (/RE) pin.
* -1 if not used.
*/
ModbusSerial (Stream & port, byte slaveId, int txenPin = -1);
/**
* @brief Configure ModbusSerial object
*
* configures txenPin on output if necessary and calculates the times of the RTU frame.
*
* @warning the \c begin() function of the serial port passed to the constructor
* must be called **BEFORE** calling this function.
*
* @param baud baudrate in accordance with that used by the serial port
*/
void config (unsigned long baud);
/**
* @brief Task that performs all operations on MODBUS
*
* Call once inside loop(), all magic here !
*/
void task();
/**
* @brief Change the value of slave identifier
* @param slaveId identifier 1-247
*/
void setSlaveId (byte slaveId);
/**
* @brief Return slave identifier
*/
byte getSlaveId();
/**
* @brief Broadcast address
*/
static const byte BroadcastAddress = 0;
protected:
bool receive (byte * frame);
bool sendPDU (byte * pduframe);
bool send (byte * frame);
void reportServerId();
private:
Stream * m_stream;
int m_txenPin;
byte m_slaveId;
unsigned int m_t15; // inter character time out (us)
unsigned int m_t35; // frame delay (us)
private:
word calcCrc (byte address, byte * pduframe, byte pdulen);
};