[0.1.0] - 2023-12-29

  • First working version. But without pressure sensor. Physical RS485 bus untested, but did test ModBus over TTL serial.

[0.2.0] - 2024-01-04

Added

  • BMP280 pressure sensor via I2C

Fixed

  • Calibrated wind vane (analog input)

Changed

  • Heater of humidiy sensor only on when humidity is above 96% (was 80%). When heater is on temperature sensor also heats up, so use temperature sensor of BMP280 when heater is on.

[0.2.1] - 2024-01-17

Changed

  • Heater algorithm updated. Idea from datasheet of humidity sensor from Temco Controls HUM-M2 humidity sensor module.
  • ModBus read register 1: Scaled wind direction by 10 in order to also get the decimal position of the direction

Added

  • ModBus read register 12: Raw rain meter
  • ModBus read register 13: Temperature from pressure sensor
  • ModBus read register 14: Status bits
  • ModBus coil register 0 : enable/disable heather algorithm

[0.2.2] - 2024-01-21

Fixed

  • Buffer overflow when calculating average wind speed in AverageOfArray(). Fix: use 32 bit register for average_value.

Changed

  • Changed some variables to the propper standard (uint8_t, uint16_t, etc.)
  • SparkFun wind interrupt now calculates over 3 seconds in stead of 1 second (KNMI standard)]

[0.2.3] - 2024-02-28

Changed

  • Humidity often got stuck at 100%. Heater algorithm now heats for 10 minutes and cools down for 10 minutes (was 5min/15min)

[0.2.4] - 2024-03-08

Changed

  • Humidity timer back to 5/15 minutes: shorter cooling times give false temperature readings.

Fixed

  • Classic 0/1 error in max and average calculating routine, which resulted in a buffer overflow.

[0.2.5] - 2024-03-11

Fixed

  • 0/1 error in max and average (again, or better said: still!).

Changed

  • Humidity threshold heater is now a define instead of hard coded numbers in the source.

[0.2.6] - 2024-03-13

Fixed

There is a bug in the Si7021 chip: when the sensor is exposed to extreme environmental conditions for a longer period (very high or very low humidity), the humidity register will wrap around and give wrong values. (https://community.silabs.com/s/question/0D51M00007xeOo9SAE/si7021-relative-humidity-reading-underflowing-?language=en_US). Workaround: let's assume the humidity will never go below 15%. In the Netherlands a humidity below 20% is rare, but can occur and the minimum value ever measured in De Bilt was 6% (on 1 april 1965). At several other sites in the Netherlands the humidity went as low as 10%. But as this was a one time event and the measurements are doubtful, this event was not registered in the original database. (https://nl.wikipedia.org/wiki/Relatieve_luchtvochtigheid) In rare cases, the humidity value could creep up above 15% (when the actual humidity is 100%) and still give wrong values.

[0.3.0] - 2024-05-02

Added

Support for HYT-221 humidity sensor

Removed

Support for si7021 humidity sensor (this sensor was not suited for outdoor measurments)